Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.269
Filtrar
2.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38658894

RESUMEN

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Asunto(s)
Terapia por Láser , Lentes Intraoculares Multifocales , Facoemulsificación , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Facoemulsificación/métodos , Agudeza Visual/fisiología , Persona de Mediana Edad , Terapia por Láser/métodos , Anciano , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares/métodos , Seudofaquia/fisiopatología , Resultado del Tratamiento , Diseño de Prótesis , Extracción de Catarata/métodos , Estudios de Seguimiento
3.
Int Ophthalmol ; 44(1): 198, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662107

RESUMEN

PURPOSE: Cataract surgery in microphthalmic eyes is challenging due to anatomical restraints, hard bulky nucleus. This series aims to evaluate the safety and efficacy of couching of intraocular lens in irido-fundal coloboma with microphthalmos. SETTING: Tertiary care centre in South India. DESIGN: Retrospective non-comparative study in eyes with irido-fundal coloboma, corneal diameter < 7 mm and brown cataract. Visual acuity less than 6/60 in other eye. METHODS: Anterior chamber entry made, zonules broken and lens dislocated into the vitreous cavity in a controlled manner. Baseline Clinico-demographic details, corrected distance visual acuity (CDVA), Intra-ocular pressure (IOP), corneal diameter, axial length, lens status and post-surgery CDVA, IOP and complications recorded and followed up for atleast 6 months. RESULTS: Fifteen eyes of 15 subjects were evaluated with a mean age 49.4 ± 10.9 years. At baseline, mean IOP 14.5 ± 3.8 mmHg, mean axial length 19.3 ± 0.5 mm, mean corneal diameter was 6.5 ± 0.34 mm and CDVA 2 logMAR which improved to 1.5 logMAR at 3 months (p value 0.002). Transient spike in IOP in 33.3% subjects was medically managed with no significant difference in IOP (p > 0.05) at baseline (14.5 ± 3.8 mmHg), 3 months post-surgery (16 ± 2.8 mmHg) and 6 months post-surgery (14.9 ± 2.5 mmHg). One patient underwent re-couching. No other major complications were noted. CONCLUSION: Couching of cataractous lens is an effective and safe method in microphthalmic eyes with irido-fundal coloboma as last resort procedure, where no other surgical procedure may work. It provides an ambulatory gain of visual acuity in previously non-ambulatory subjects. Corneal measurements help in determining the subset of patients where couching offers viable option.


Asunto(s)
Catarata , Coloboma , Microftalmía , Agudeza Visual , Humanos , Estudios Retrospectivos , Femenino , Coloboma/diagnóstico , Coloboma/complicaciones , Coloboma/cirugía , Masculino , Microftalmía/complicaciones , Microftalmía/diagnóstico , Microftalmía/cirugía , Catarata/complicaciones , Catarata/congénito , Catarata/diagnóstico , Persona de Mediana Edad , Adulto , Iris/cirugía , Iris/anomalías , Implantación de Lentes Intraoculares/métodos , Extracción de Catarata/métodos , Cristalino/anomalías , Cristalino/cirugía , Estudios de Seguimiento
4.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38644781

RESUMEN

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Asunto(s)
Lentes Intraoculares Multifocales , Presbiopía , Diseño de Prótesis , Refracción Ocular , Agudeza Visual , Humanos , Estudios Prospectivos , Femenino , Masculino , Agudeza Visual/fisiología , Anciano , Persona de Mediana Edad , Presbiopía/fisiopatología , Presbiopía/cirugía , Refracción Ocular/fisiología , Visión Binocular/fisiología , Satisfacción del Paciente , Sensibilidad de Contraste/fisiología , Facoemulsificación , Estudios de Seguimiento , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares
5.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651698

RESUMEN

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Esclerótica , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Esclerótica/cirugía , Implantación de Lentes Intraoculares/métodos , Estudios Prospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología , Colgajos Quirúrgicos , Técnicas de Sutura , Seudofaquia/fisiopatología , Refracción Ocular/fisiología
6.
Klin Monbl Augenheilkd ; 241(4): 374-377, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38653291

RESUMEN

BACKGROUND: In cataract surgery, intraocular lenses (IOLs) with enhanced depth of focus are an option to correct presbyopia. The purpose of this quality assurance analysis was to evaluate visual acuity and patient satisfaction after implantation of the Hoya Vivinex Impress IOL. METHODS: The Hoya Vivinex Impress IOL was implanted in patients undergoing cataract surgery at the Pallas Klinik, Olten, Switzerland. Five weeks postoperatively, a clinical examination and a survey on patient satisfaction were conducted. RESULTS: A total of 17 eyes (9 patients; mean age 64 years) underwent cataract surgery with implantation of a Hoya Vivinex Impress IOL. Five weeks postoperatively, mean uncorrected distance visual acuity (UDVA) was 0.2 logMAR, uncorrected intermediate visual acuity (UIVA) was 0.0 logMAR, and uncorrected near visual acuity (UNVA) was 0.2 logMAR. The mean distance-corrected visual acuity results were 0.0 logMAR, 0.1 logMAR, and 0.3 logMAR, respectively. Reading the newspaper without glasses was possible for 33.4% of patients. Visual disturbances such as halos and glares were not reported. CONCLUSION: Cataract surgery with Hoya Vivinex Impress IOL implantation revealed good distance and intermediate vision and, in some patients, functional near vision as well as a high patient satisfaction.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Satisfacción del Paciente , Diseño de Prótesis , Agudeza Visual , Humanos , Femenino , Persona de Mediana Edad , Masculino , Resultado del Tratamiento , Anciano , Implantación de Lentes Intraoculares/métodos , Percepción de Profundidad/fisiología , Análisis de Falla de Equipo , Extracción de Catarata/métodos
7.
J Refract Surg ; 40(4): e199-e207, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593258

RESUMEN

PURPOSE: To investigate the efficacy of incorporating Generative Adversarial Network (GAN) and synthetic images in enhancing the performance of a convolutional neural network (CNN) for automated estimation of Implantable Collamer Lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT). METHODS: This study was a retrospective evaluation using synthetic data and real patient images in a deep learning framework. Synthetic ICL AS-OCT scans were generated using GANs and a secondary image editing algorithm, creating approximately 100,000 synthetic images. These were used alongside real patient scans to train a CNN for estimating ICL vault distance. The model's performance was evaluated using statistical metrics such as mean absolute percentage error (MAPE), mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination (R2) for the estimation of ICL vault distance. RESULTS: The study analyzed 4,557 AS-OCT B-scans from 138 eyes of 103 patients for training. An independent, retrospectively collected dataset of 2,454 AS-OCT images from 88 eyes of 56 patients, used prospectively for evaluation, served as the test set. When trained solely on real images, the CNN achieved a MAPE of 15.31%, MAE of 44.68 µm, and RMSE of 63.3 µm. However, with the inclusion of GAN-generated and algorithmically edited synthetic images, the performance significantly improved, achieving a MAPE of 8.09%, MAE of 24.83 µm, and RMSE of 32.26 µm. The R2 value was +0.98, indicating a strong positive correlation between actual and predicted ICL vault distances (P < .01). No statistically significant difference was observed between measured and predicted vault values (P = .58). CONCLUSIONS: The integration of GAN-generated and edited synthetic images substantially enhanced ICL vault estimation, demonstrating the efficacy of GANs and synthetic data in enhancing OCT image analysis accuracy. This model not only shows potential for assisting postoperative ICL evaluations, but also for improving OCT automation when data paucity is an issue. [J Refract Surg. 2024;40(4):e199-e207.].


Asunto(s)
Cristalino , Miopía , Lentes Intraoculares Fáquicas , Humanos , Tomografía de Coherencia Óptica/métodos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Miopía/cirugía
8.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593262

RESUMEN

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Asunto(s)
Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/diagnóstico , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Facoemulsificación/métodos , Óptica y Fotónica , Refracción Ocular , Biometría/métodos
9.
BMC Ophthalmol ; 24(1): 154, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594683

RESUMEN

BACKGROUND: Intraocular lens (IOL) fixation is performed after intraoperative anterior or total vitrectomy. This study aimed to compare the intraoperative and postoperative complications of these two techniques. METHODS: This retrospective study included 235 eyes that underwent intrascleral fixation surgery at our hospital between July 2014 and January 2021. The eyes were classified into the anterior vitrectomy group (A-vit group; 134 eyes) and the pars plana vitrectomy group (PPV group; 101 eyes). The age, preoperative and postoperative best-corrected visual acuity, observation period, preoperative and postoperative intraocular pressure, and the incidence of intraoperative and postoperative complications were assessed. RESULTS: Intrascleral fixation was performed more frequently in the PPV group, and a significant difference was observed between the eyes with a history of vitrectomy and eyes with scleral buckles (p = 0.00041). In terms of the incidence of postoperative complications following intrascleral fixation, the incidence of low intraocular pressure postoperative was higher in the PPV group than that in the A-vit group, and a significant difference was observed between the two groups (p = 0.01). CONCLUSIONS: The visual outcome and complications following intrascleral fixation did not differ according to the extent of vitreous excision.


Asunto(s)
Lentes Intraoculares , Vitrectomía , Humanos , Vitrectomía/efectos adversos , Vitrectomía/métodos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Agudeza Visual , Esclerótica/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía
10.
J Refract Surg ; 40(3): e142-e147, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38466767

RESUMEN

PURPOSE: To evaluate the accuracy of the Reinstein formula with hand-held ultrasound biomicroscopy (UBM) measurements for sizing of the Implantable Collamer Lens (ICL). METHODS: A total of 107 myopic eyes of 57 patients implanted with the ICL were included in the study. The size of the ICL was selected based on the manufacturer's recommendations. Agreement between the vault predicted by the Reinstein formula and the vault measured postoperatively was analyzed with Bland-Altman plots. RESULTS: A total of 95% and 81% of patients had a postoperative vault ranging from 150 to 1,000 and 250 to 750 µm, respectively. The mean vault predicted by the Reinstein formula and the postoperative vault in the current study were 580 ± 181 and 547 ± 200 µm, respectively. The size recommendations of the Reinstein formula and the formula provided by the manufacturer, the Kojima formula, and the Dougherty formula overlapped in 50%, 57%, and 49% of eyes, respectively. CONCLUSIONS: The results show that the Reinstein formula combined with a hand-held UBM provides reliable sizing predictions of the ICL. However, considering that robotic UBM measurements have demonstrated a narrower range of deviation in predicting vault depth in previous studies, a direct comparison study between robotic UBM and hand-held UBM measurements is necessary to fully assess the limitations of combining hand-held UBM with the Reinstein formula. [J Refract Surg. 2024;40(3):e142-e147.].


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Microscopía Acústica/métodos , Implantación de Lentes Intraoculares/métodos , Agudeza Visual , Miopía/cirugía , Estudios Retrospectivos
11.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38466765

RESUMEN

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Asunto(s)
Cristalino , Miopía , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares/métodos , Miopía/cirugía , Acomodación Ocular , Cámara Anterior/diagnóstico por imagen , Seudofaquia/cirugía , Tomografía de Coherencia Óptica , Biometría
12.
Sci Rep ; 14(1): 6181, 2024 03 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485976

RESUMEN

This study aimed to compare the outcomes of flanged intraocular lens (IOL) fixation with new IOL exchange after dislocated IOL removal and repositioned dislocated IOL in patients with IOL dislocation. Eighty-nine eyes that underwent flanged IOL fixation were retrospectively included, with 51 eyes in the exchanged IOL group and 38 eyes in the repositioned IOL group. In both groups, best-corrected visual acuity (BCVA) improved at 1, 3, 6, and 12 months postoperatively and did not differ between the two groups at any of these time points. However, at 1 week postoperatively, BCVA in the repositioned IOL group improved compared with baseline, whereas that in the exchanged IOL group did not. Moreover, there were lesser changes in the corneal endothelial cell density (ECD) and corneal astigmatism in the repositioned IOL group than in the exchanged IOL group. The IOL positions, including IOL tilt and IOL decentration, were not different between the groups. Flanged IOL fixation with new IOL exchange and with repositioned dislocated IOL for patients with IOL dislocation had similar visual outcomes and IOL position. However, the latter had a smaller corneal ECD decrease and astigmatic change. This technique was effective in treating IOL dislocation while minimizing corneal injury.


Asunto(s)
Subluxación del Cristalino , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Agudeza Visual , Subluxación del Cristalino/cirugía , Técnicas de Sutura , Complicaciones Posoperatorias/cirugía
13.
Ophthalmic Res ; 67(1): 248-256, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38527448

RESUMEN

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Asunto(s)
Cámara Anterior , Subluxación del Cristalino , Lentes Intraoculares , Refracción Ocular , Humanos , Masculino , Femenino , Anciano , Refracción Ocular/fisiología , Persona de Mediana Edad , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/fisiopatología , Adulto , Agudeza Visual , Estudios Retrospectivos , Óptica y Fotónica , Implantación de Lentes Intraoculares/métodos , Biometría/métodos , Anciano de 80 o más Años
14.
Int Ophthalmol ; 44(1): 151, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38507136

RESUMEN

PURPOSE: To identify the rate and characteristics of cataract surgery candidates suitable for multifocal intraocular lens implantation among patients undergoing preoperative evaluation in a public hospital. MATERIALS AND METHODS: Screening was performed based on the patient's medical records, comprehensive ophthalmic examination, optical biometry (Zeiss, IOL Master 700) and optical coherence tomography (OCT) (Heidelberg, OCT Spectralis) in accordance with the relevant indications and contraindications mentioned in the pertinent literature. Patients were included in the present study if they were eligible for bilateral cataract surgery. The exclusion criteria were the presence of central nervous system or motility issues, prior refractive surgery, the presence of astigmatism greater than 1 dioptre and/or the presence of important ocular comorbidities in either eye. RESULTS: The study evaluated 1200 consecutive patients. Four hundred thirty-two patients (36%) were not eligible for bilateral surgery and were excluded from the study. Of the 768 patients included in the present study, 346 (45.1%) were considered suitable candidates. Four hundred twenty-two patients (54.9%) were excluded for one or both eyes. Among them, 121 (28.7%) were excluded because of retinal disease, 120 (28.4%) because of regular astigmatism (> 1.0 D of corneal astigmatism), 32 (7.5%) because of pseudoexfoliation or zonular instability, and 30 (7.1%) because of glaucoma or ocular hypertension; in addition, 90 (21.3%) patients were excluded for multiple reasons. Suitable candidates were significantly younger (70 and 75 years, respectively) (p < 0.001). After being informed about the potential risks and benefits of MOIL implantation, 212 of 346 (83.8%) eligible patients provided consent. CONCLUSION: Close to half of cataract patients in a public hospital were eligible for MOIL implantation, and the majority of patients would proceed to surgery. The most prevalent contraindication was macular disease.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares/efectos adversos , Agudeza Visual , Facoemulsificación/métodos , Catarata/complicaciones , Catarata/epidemiología , Refracción Ocular
15.
Int Ophthalmol ; 44(1): 152, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38509438

RESUMEN

PURPOSE: To evaluate and compare the clinical outcomes of three different methods of intraocular lens (IOL) implantation in the surgery of subluxated cataracts. METHODS: In this retrospective, comparative, clinical interventional study, the medical records of patients who underwent IOL implantation with sutureless 27-gauge needle-assisted transconjunctival intrascleral (Group 1), Z-suture knotless transscleral (Group 2), and Cionni capsular tension ring (Cionni-CTR) assisted (Group 3) simultaneously with subluxated cataract extraction between June 2010 and June 2022 were evaluated. Demographic characteristics, follow-up times, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical and cylindrical refractive values, and spherical equivalent (SE) values of three groups were compared. Intraoperative and postoperative complications were recorded. RESULTS: There were 20 eyes in Group 1, 35 eyes in Group 2, and 40 eyes in Group 3. In all groups, statistically significant improvement was observed in postoperative UDVA and CDVA compared to preoperative values (each p < 0.05). There was no statistical difference between the groups in postoperative UDVA and CDVA values. (p = 0.130, p = 0.167 respectively). No significant difference was observed between the groups in terms of postoperative spherical, cylindrical, and SE values (each p > 0.05). CONCLUSION: The study suggests that three different IOL implantation techniques for simultaneous IOL implantation in subluxated cataract surgery have similar effects on visual and refractive outcomes.


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Extracción de Catarata/efectos adversos , Catarata/complicaciones , Suturas/efectos adversos
16.
Ophthalmic Res ; 67(1): 221-231, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38493781

RESUMEN

INTRODUCTION: The aim of this study was to investigate the efficacy of new monofocal intraocular lens (IOL) in comparison with conventional monofocal IOL in patients undergoing combined cataract and vitrectomy surgery for epiretinal membrane (ERM). METHODS: This prospective non-randomized comparative study included 65 eyes of 65 patients who underwent combined cataract and vitrectomy for ERM with implantation of advanced monofocal IOL (Eyhance ICB00, 33 patients) and standard monofocal IOL (Tecnis ZCB00, 32 patients). Monocular visual acuities were measured 6 months post-operatively, including corrected and uncorrected distance visual acuity (CDVA, UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA). Furthermore, contrast sensitivity and metamorphopsia were measured. RESULTS: There was no significant difference between two groups regarding operation time, post-operative CDVA, UCDVA, UCNVA, and spherical equivalent (p > 0.05). Monocular UCIVA was significantly higher in the Eyhance IOL group than in the Tecnis IOL group (p = 0.005). The photopic and mesopic contrast sensitivities were comparable between each group for any spatial frequency (p > 0.05). The correlation coefficients from correlations between retinal wrinkling ratio and M score did not differ significantly between groups (p = 0.877), and the degree of metamorphopsia was not significantly related to the type of IOL (p = 0.969). CONCLUSIONS: In combined cataract and vitrectomy for ERM, Eyhance IOL provided significant better visual performance at intermediate distance than standard monofocal IOL without compromising operation time, distance vision, contrast sensitivity, and evaluating metamorphopsia. Eyhance IOL can be a useful option for both surgeons and patients.


Asunto(s)
Catarata , Membrana Epirretinal , Implantación de Lentes Intraoculares , Lentes Intraoculares , Agudeza Visual , Vitrectomía , Humanos , Vitrectomía/métodos , Femenino , Masculino , Agudeza Visual/fisiología , Estudios Prospectivos , Membrana Epirretinal/cirugía , Membrana Epirretinal/fisiopatología , Membrana Epirretinal/diagnóstico , Anciano , Persona de Mediana Edad , Catarata/fisiopatología , Catarata/complicaciones , Implantación de Lentes Intraoculares/métodos , Sensibilidad de Contraste/fisiología , Diseño de Prótesis , Estudios de Seguimiento , Resultado del Tratamiento , Facoemulsificación/métodos
17.
Sci Rep ; 14(1): 3484, 2024 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-38346992

RESUMEN

Sulcus-to-sulcus vertical diameter is longer than the horizontal. However, the effect of vertical positioning of the implantable collamer lens (ICL) on the vault compared to preoperative prediction is unclear. This prospective consecutive case series aimed to examine postoperative and preoperative predicted vaults during vertical ICL fixation. This study assessed 180 right eyes in 180 patients with myopic astigmatism. For the 90 eyes in 90 patients who underwent horizontal fixation (horizontal group) and 90 eyes in 90 patients who underwent vertical fixation (vertical group), biometrics by three-dimensional tomography of the anterior segment optical coherence tomography (A-OCT) was performed before surgery and 2 h, 1 day, 1 week, 1 month and 3 months after surgery. The anterior chamber depth did not change over time in both groups, and there was no significant difference from preoperative values. The postoperative vault values were significantly lower in the vertical group than in horizontal group over time. The difference between vault measurements and preoperative predictions at all postoperative time points was significantly greater in the vertical group than in horizontal group. Vertical fixation of the ICL reduced the vault by > 100 µm compared with horizontal fixation, which was different from the A-OCT preoperative predicted value.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Estudios Prospectivos , Miopía/cirugía , Implantación de Lentes Intraoculares/métodos , Ojo , Estudios Retrospectivos
18.
Int Ophthalmol ; 44(1): 54, 2024 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-38341384

RESUMEN

OBJECTIVE: To compare the visual performance of two presbyopia-correcting intraocular lenses (IOLs) that combine both bifocal and extended depth-of-focus profiles, Artis® Symbiose® Plus (Symbiose Plus; Cristalens Industrie, Lannion, France) and Tecnis® Synergy® (Synergy; Johnson & Johnson Vision, Santa Ana, CA, USA). METHODS: The medical records of patients with cataract bilaterally implanted with either Symbiose Plus or Synergy between January 2022 and January 2023 were assessed. The principal measures of postoperative findings included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near (40 and 33 cm) visual acuity (UNVA), objective optical quality (OOQ) parameters, distance-corrected defocus curve analysis, and surveys of subjective satisfaction. RESULTS: Total of 96 eyes from 48 patients were enrolled. Each group was equally composed of 24 patients, 48 eyes. There were no significant differences between the two groups on baseline characteristics. Both IOLs displayed excellent binocular UDVA, CDVA, and UNVA (40 and 33 cm) with no statistical difference (p = 0.467(UDVA), p = 0.584(CDVA), p = 0.096(40-cm UNVA), and p = 0.621(33-cm UNVA)). However, with regard to UIVA, the Synergy group showed significantly superior results (p < 0.001). In contrast, the Symbiose Plus group showed significantly better results on OOQ parameters and patient-reported quality of vision survey outcomes (both p < 0.001). CONCLUSIONS: Both IOLs provided a decent continuous range of vision from near to far distance.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Presbiopía , Humanos , Refracción Ocular , Implantación de Lentes Intraoculares/métodos , Presbiopía/cirugía , Satisfacción del Paciente , Diseño de Prótesis , Visión Binocular
19.
J Refract Surg ; 40(2): e108-e116, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38346117

RESUMEN

PURPOSE: To explore a potential functional classification of intraocular lenses (IOLs) based on monocular visual acuity defocus curves (VADCs) as a primary end-point. METHODS: A systematic literature search was conducted using PubMed. Two independent reviewers screened the literature for inclusion and data extraction. Inclusion criteria were full-text primary clinical studies of IOLs, published in English from 2010 onward, involving patients undergoing cataract or refractive lens exchange. A cluster analysis was conducted to explore similarities in the range of field (RoF) and increase of visual acuity from intermediate to near (ΔVA). RESULTS: A total of 107 studies were ultimately included from the 436 identified in the systematic search, with an additional 5 studies added through the snowballing technique search. The cluster analysis was conducted using 69 reports that included monocular VADCs. Two main categories were identified based on the achieved RoF for 0.2 and 0.3 logMAR: full (FRoF) and partial (PRoF) RoF IOLs. Three subcategories were identified for FRoF depending on ΔVA: continuous (FRoF-C), smooth (FRoF-Sm), and steep (FRoF-St). On the other hand, PRoF IOLs shared the characteristic of monotonous decrease in visual acuity and were subclassified into two subcategories depending on the achieved RoF: narrowed (PRoF-N) and extended (PRoF-Ex). An additional subcategory was added to PRoF, enhanced (PRoF-En), for 7 reports alternating between PRoF-N and PRoF-Ex depending on the use of 0.2 or 0.3 logMAR as a cut-off for calculating the RoF. CONCLUSIONS: IOLs can be functionally classified into six types depending on the RoF and shape of the monocular VADC. [J Refract Surg. 2024;40(2):e108-e116.].


Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Agudeza Visual , Análisis por Conglomerados , Diseño de Prótesis , Satisfacción del Paciente
20.
Int Ophthalmol ; 44(1): 46, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336905

RESUMEN

PURPOSE: To determine the toric intraocular lens (IOL) axis by using internal astigmatism axis obtained from Optical Path Difference (OPD) Scan III (Nidek Co.) in non-dilate eyes. METHODS: The eyes of patients who underwent toric IOL implantation for astigmatic correction were investigated. Patients who have ocular surface disorder, keratoconus, posterior capsule opacification were excluded. The IOL axis measured in non-dilated eyes in mesopic conditions by OPD scan III device and the IOL axis measured by using classical slit lamp biomicroscopy method in dilated eyes were detected at postoperative 1st and 6th months. Results were compared with correlation and linear regression analysis. RESULTS: Totally, 26 eyes of 18 patients were included. The difference between biomicroscopic IOL axis and OPD internal astigmatism axis was 4.96 ± 4.41 degrees at the 1st month and 3.62 ± 3.5 degrees at the 6th month. There was a significant and high correlation between biomicroscopic IOL axis and OPD internal astigmatism axis at both 1st month (r = 0.992 p < 0.001) and 6th month (r = 0.995 p < 0.001). According to regression analysis, the results of two measurement methods were significantly compatible with each other at 1st month (R Sq = 0.984 p < 0.001) and 6th month (R Sq = 0.990 p < 0.001) and there was a close to ideal linear (R Sq = 1) relationship between two methods. CONCLUSIONS: In eyes with toric IOL implantation, the IOL axis and IOL rotation according to target IOL axis can be detected easily and effectively in a short time by OPD scan internal astigmatism axis without the need to dilate the pupil.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Agudeza Visual , Facoemulsificación/métodos , Astigmatismo/cirugía , Refracción Ocular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...